1 0 Copper Wire Ampacity
Current is measured in amperes or amps.
1 0 copper wire ampacity. Fep fepb mi rhh rhw 2 sa sis tbs thhn thhw thw 2 thwn 2 use 2 xhh xhhw xhhw 2 zw 2 unless otherwise specifically permitted elsewhere in the nec nfpa70 code the overcurrent protection for conductor types marked with an asterisk shall not exceed 15a for no. 14 awg 12 awg 10 awg 8 awg 6 awg 4 awg 3 awg 2 awg 1 awg 1 0 awg 2 0 awg 3 0 awg 4 0 awg 250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil 700 kcmil 750 kcmil 800 kcmil 900 kcmil. The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor. Wire cable type.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating. For application of this section the main. Copper neutral supported multiplex overhead service drop. Turns of wire no insulation.
Kcmil circular mils x 1000. For example 3 0 awg copper has an ampacity of 200 amps at 75 while 3 0 awg aluminum has an ampacity of 155 amps at 75. Usually a general purpose house circuit is designed for 20. The following table of wire sizes does not show any sizes bigger than 4 0 gauge because solid copper wire becomes impractical to handle at those sizes.
Rhw thhw thw thwn xhhw zw 90 c 194 f. Csa teck 90 non shielded cables. The following calculator calculates the voltage drop and voltage at the end of the wire for american wire gauge from 4 0 awg to 30 awg aluminum or copper wire. 60 c 140 f 75 c 167 f awg mm copper.
Wire ampacity calculator enter the information below to calculate the maximum allowable ampacity for current carrying conductors. Insulated wire types like thhn thwn 2 xhhw 2 and use 2 rhh rhw 2 have an insulation temperature rating of 90 and any temperature correction factors or ampacity adjustment factors can be applied. 14 copper 20a for no. Nec copper wire ampacity with 60 75.
Ordering strong brand names. It just calculates the voltage drop consult the above table for rules of thumb or your local or national electrical code or your electrician to decide what is legal. The tables below are intended to be a general guide for wire size and amp ratings. 120 240 volt 3 wire single phase service entrance conductors service lateral conductors and feeder conductors that serve as the main power feeder to a dwelling unit and are installed in raceway or cable with or without an equipment grounding conductor.
1 the load current rating and the overcurrent protection for conductor types shall not exceed 15 amperes for 14 awg 20 amperes for 12 awg and 30 amperes for 10 awg aluminum and copper clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.